Help 4D probe; realize the probe through the ID code; change the 4D generate sign by means of the electrical relay to make the 4D probe work Generally. four.two.2 Main board The main board might be divided into two sections: entrance-conclusion of the most crucial board and back again-close of the most crucial board.
Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat depth login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.
NOTE: Within the keep an eye on, the brightness adjustment will come just before contrast. Immediately after readjusting the keep track of’s contrast and brightness, modify all preset and peripheral settings.
Will not use any cables apart from the cables supplied While using the system by Mindray. three. Use the cable furnished with This method to attach the printer. Other cables may possibly bring about electrical shock. Web site fifteen: Mechanical Protection
Lower off cable ties connecting the principle unit around the Display screen by diagonal chopping pliers, then pull out the corresponding cable plugs.
Mindray’s new generation of black & white ultrasound method, DP-50 Expert, is provided with Sophisticated imaging systems allowing for deeper penetration and more quickly image acquisition with higher resolution.
Site 145 Clean control panel Applications: dry comfortable fabric, mild soapy drinking water Method: Use dry smooth fabric to clean the surface area with the system. In case the system is dirty, moisten the smooth fabric with moderate soapy h2o and wipe off any stains. Use dry soft cloth to remove any moisture and allow all really hard surfaces to entirely air-dry. Page 146: Cleanse The Peripherals
Find greater diagnostic data by extended look at in the anatomical construction on all convex probes.
Permits usage of many scanned angles to form one image, leading to Improved distinction resolution and enhanced visualization
5.2.3 Geometric positioning precision Longitudinal geometric positioning accuracy Test Step: Do changes as the way in tests the maximum depth. Report the gap by 20mm each segment within the longitudinal targets line utilizing the measurement caliper; Decide on the worth with the best mistake (to 20mm), calculate the accuracy using the components below The measurement caliper should be positioned for the higher fringe of the target, Be aware:... Webpage seventy nine Transverse geometric positioning accuracy Take a look at Phase: Include the scan surface area in the phantom with h2o or few gel, Carefully Call the probe Together with the scan surface Change the depth, producing the transverse targets to get shown from the image. Alter the main focus position to generally be posited beside the transverse targets (the normal is not really distinct) Regulate parameters like gain, TGC, making Each individual transverse targets for being Obviously exhibited. Web page eighty five.five.two.four Blackout Place Exam Move: Deal with the scan area from the phantom with drinking water or few gel, Carefully contact the probe Together with the scan surface area Change the depth in a reduce price, and established the focus at the closest spot to the scan surface area. Lessen the value of parameters like AP, Obtain until eventually the history noise just may be witnessed. Site 81: Software Enhance And Routine maintenance
Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.
Discover improved diagnostic information through prolonged perspective in the anatomical construction on all linear probes
Performance Check 5.5.1 Take a look at Method Resolution Detection depth Geometric Posture Precision Blackout location take a look at Document the Examination pictures 5.5.2 Take a look at Written content The graphic utilised here is only for reference, persist with the impression result in the true Observe: condition. Specifications: Display: established the contrast and brightness for the clinical application Dp50rb login benefit (or even the default status) Operation environment: darkish home, simulating the clinical application atmosphere. Webpage 76 In affliction which the transverse resolution screening targets are horizontally exhibited, document the nominal length of two targets which might be Evidently identified. Repeat the Procedure previously mentioned for your transverse resolution testing targets at other depths. As demonstrated in figure underneath. Axial resolution ... Website page seventy seven When using the convex probe, continue to keep the transverse resolution testing targets to NOTE: be exhibited near the midline. When employing a linear probe with steer perform, tend not to activate the steer purpose when carry out the transverse resolution test. Zoom in the area where the targets Situated if required. The diameter with the target issue at a specific depth is equal for the transverse resolution in the depth. Webpage 78 five.
Your Instrument for further biopsy: allowing adjustments on the scan line to gain better visibility from the needle, nerves and tiny vessels, guaranteeing the continuity of all info.
Take note: Ensure that you can pull out and force into your IO board sockets vertically when pulling out and assembling the IO board assembly about the position with the manage. Remove panhead screws with washers M3X6 (4) used to secure the IO board, and afterwards you could potentially take out the IO board. Web page 116 Take out panhead screws with washers (2 M3X6) that are set on the key unit, consider out the upper baffle and then pull out two cables connecting the principle board to the facility module assembly.